Back to Top

1
Hi, Guest!
  • ProMinent
  • Diaphragm Metering Pump ProMinent EXtronic®

Diaphragm Metering Pump ProMinent EXtronic®

Update Terakhir
:
10 / 05 / 2021
Min. Pembelian
:
1 Unit

Harga

CALL

Detail Diaphragm Metering Pump ProMinent EXtronic®

Diaphragm Metering Pump ProMinent EXtronic®

Capacity range of single head pump: 1 – 60 l/h; 25 – 1 bar

The diaphragm metering pump EXtronic® is perfectly suited for the sensitive use of liquid media in facilities with an explosive gas atmosphere as well as for mines at risk of firedamp, as it is approved in compliance with the EU EX Regulation 2014/34/EU (ATEX). (diaphragm pump)

Technical Details

  • Stroke length: 1.25 mm, Rod force: 2,000 N
  • Stroke length adjustment range: 0 – 100% in operation and idle
  • Stroke length adjustment: manually by scaled rotary dial
  • Metering reproducibility is better than ± 2% within the 30 – 100% stroke length range under defined conditions and with correct installation. Observe the information in the operating instructions
  • DEVELOPAN® metering diaphragm with PTFE coating with diaphragm rupture control
  • Wetted materials: Polypropylene, PVC, PTFE with carbon, clear acrylic, stainless steel, special designs available on request
  • Degree of protection: IP 65 (also with open front cover)
  • Short stroke solenoid drive and complete pump control integrated in the pump housing
  • "Internal", "External contact" and "Analogue" control inputs are available, the latter two also available as intrinsically safe and approved to EN 60079-11
  • EXBb G for use in areas at risk from gases and vapours, degree of protection EEx [i,a] d IIC T6

This means:

  • EEx - Equipment complies with European standards
  • [i,a] - Control input is intrinsically safe when 2 independent errors occur
  • d - Type of ignition protection, compression-resistant enclosure
  • IIC - Explosion group II for all areas at risk from explosion with the exception of mining, sub-group IIC (includes IIA and IIB)
  • T6 - Temperature class permissible for gases and vapours with ignition temperature > 85 °C
  • EXBb M for use in mines at risk from firedamp, degree of protection EEx [i,a] d I/IIC T6

This means:

  • EEx - Equipment complies with European standards
  • [i,a] - Control input is intrinsically safe when 2 independent errors occur
  • d - Type of ignition protection, compression-resistant enclosure
  • IC - Explosion group I for mines at risk from firedamp
  • IIC - Explosion group II for all areas at risk from explosion with the exception of mining, sub-group IIC (includes IIA and IIB)
  • T6 - Temperature class permissible for gases and vapours with ignition temperature > 85 °C

Tampilkan Lebih Banyak
Kontak Kami